依次选择Utility Menu→Select→Everything。
依次选择Main Menu→Solution→FLOTRAN Set Up→Fluid Properties,会弹出“Fluid Properties”对话框,如图9-31所示,采用默认设置。
单击“OK”按钮会弹出“CFD Flow Properties”对话框,如图9-32所示,在“Density property type CONSTANT Constant value”输入框中输入RHO,在“Viscosity property type CONSTANT Constant value”输入框中输入MU,其余选项采用默认设置,单击“OK”按钮关闭该对话框。
图9-31 “Fluid Properties”对话框
图9-32 “CFD Flow Properties”对话框
依次选择Main Menu→Solution→FLOTRAN Set Up→Additional Out→RFL Out Derived,会弹出“RFL Output Derived”对话框,如图9-33所示,单击“TAUW Output wall shear stress?”后的方框,使“No”状态变为“Yes”,单击“OK”按钮关闭该对话框。
依次选择Main Menu→Solution→FLOTRAN Set Up→Mod Res/Quad Ord→CFD Quad Orders,会弹出“Quadrature Orders”对话框,如图9-34所示,在“MOMD Momentum diffusion”输入框输入2,在“MOMS Momentum source”输入框输入2,在“PRSD Pressure diffusion”输入框输入2,在“PRSS Pressure source”输入框输入2,其余采用默认设置,单击“OK”按钮关闭该对话框。
图9-33 “RFL Output Derived”对话框
图9-34 “Quadrature Orders”对话框
依次选择Main Menu→Solution→FLOTRAN Set Up→Solution Options,会弹出“FLOTRAN Solution Options”对话框,如图9-35所示,在“TRAN Steady state or transient?”选择列表中选择“Transient”;单击“FLOW Solve flow equations?”后的方框,使“No”状态变为“Yes”;在“TURB Laminar or turbulent?”选择列表中选择“Laminar”;单击“ALE Allow mesh motion?”后的方框,使“No”状态变为“Yes”,其余采用默认设置,单击“OK”按钮关闭该对话框。(www.xing528.com)
图9-35 “FLOTRAN Solution Options”对话框
依次选择Main Menu→Solution→FLOTRAN Set Up→Execution Ctrl,会弹出“Time Step Controls”对话框,如图9-36所示,在“STEP Select time step control”后的选择列表选择“User defined”,在“Base output controlon”后的选择列表中选择“Both”。
图9-36 “Time Step Controls”对话框
单击“OK”按钮会弹出“Transient Controls”对话框,如图9-37所示,在“STEP User-defined time step”输入框输入delta,在“NUMB Number of times teps”输入框输入nts,在“TEND Stop time”输入框输入time,在“GLOB Global iter pertime step”输入框输入25,在“STEP,APPE Number of time steps”输入框输入appf,其余采用默认设置,单击“OK”按钮关闭该对话框。
注意
“STEP,APPE Number of time steps”输入框在对话框下面,需要拖动对话框右边的拉条才能看到。
依次选择Main Menu→Solution→Run FLOTRAN,求解完成后会弹出提示对话框,单击“Close”按钮关闭。迭代曲线如图9-38所示。
图9-37 “Transient Controls”对话框
图9-38 迭代曲线