首页 理论教育 流体力学模拟中重力场设置方法

流体力学模拟中重力场设置方法

时间:2023-06-24 理论教育 版权反馈
【摘要】:依次选择Main Menu→Solution→FLOTRAN Set Up→Flow Environment→Gravity,会弹出“Gravity Specification”对话框,如图7-23所示,在“ACELY Accel in Ydirection”输入框中输入grav,其余采用默认设置,单击“OK”按钮关闭该对话框。选择列表中选择“Turbulent”,单击“VOF Activate VOF advection?”图7-23 “Gravity Specification”对话框图7-23 “Gravity Specification”对话框图7-24 “FLOTRAN Solution Options”对话框图7-24 “FLOTRAN Solution Options”对话框图7-25 “Time Step Controls”对话框图7-25 “Time Step Controls”对话框图7-26 “Transient Controls”对话框注意“STEP,APPE Number of time steps”输入框在对话框下面,需要拖动对话框右边的拉条才能看到。

流体力学模拟中重力场设置方法

978-7-111-44902-7-Chapter07-120.jpg依次选择Main Menu→Solution→FLOTRAN Set Up→Flow Environment→Gravity,会弹出“Gravity Specification”对话框,如图7-23所示,在“ACELY Accel in Ydirection”输入框中输入grav,其余采用默认设置,单击“OK”按钮关闭该对话框。

978-7-111-44902-7-Chapter07-121.jpg依次选择Main Menu→Solution→FLOTRAN Set Up→Solution Options,会弹出“FLOTRAN Solution Options”对话框,如图7-24所示,在“TRAN Steady state or transient?”选择列表中选择“Transient”,在“TURB Laminar or turbulent?”选择列表中选择“Turbulent”,单击“VOF Activate VOF advection?”后的方框,使“No”状态变为“Yes”,其余采用默认设置,单击“OK”按钮关闭该对话框。

978-7-111-44902-7-Chapter07-122.jpg依次选择Main Menu→Solution→FLOTRAN Set Up→Execution Ctrl,会弹出“Time Step Controls”对话框,如图7-25所示,在“STEP Select time step control”后的选择列表选择“User defined”。

978-7-111-44902-7-Chapter07-123.jpg单击“OK”按钮会弹出“Transient Controls”对话框,如图7-26所示,在“STEP User-defined time step”输入框输入1e-2,在“NUMB Number of time steps”输入框输入50,在“GLOB Global iter per time step”输入框输入3,在“PRES Pressure”输入框输入1e-6,在“STEP,APPE Number of time steps”输入框输入0.1,单击“OK”按钮关闭该对话框。

978-7-111-44902-7-Chapter07-124.jpg

图7-23 “Gravity Specification”对话框

978-7-111-44902-7-Chapter07-125.jpg

图7-24 “FLOTRAN Solution Options”对话框

978-7-111-44902-7-Chapter07-126.jpg

图7-25 “Time Step Controls”对话框

978-7-111-44902-7-Chapter07-127.jpg

图7-26 “Transient Controls”对话框

注意

“STEP,APPE Number of time steps”输入框在对话框下面,需要拖动对话框右边的拉条才能看到。

978-7-111-44902-7-Chapter07-128.jpg依次选择Main Menu→Solution→FLOTRAN Set Up→Advection,会弹出“Advection Option”对话框,如图7-27所示,确认“MOME Momentum equations”后要选择“SUPG”,其余采用默认设置,单击“OK”按钮关闭该对话框。

978-7-111-44902-7-Chapter07-129.jpg依次选择Main Menu→Solution→FLOTRAN Set Up→Relax/Stab/Cap→DOF Relaxation,会弹出“DOF Relaxation”对话框,如图7-28所示,在“PRES Pressure relaxation”输入框输入1,其余采用默认设置,单击“OK”按钮关闭该对话框。

978-7-111-44902-7-Chapter07-130.jpg依次选择Main Menu→Solution→FLOTRAN Set Up→Fluid Properties,会弹出“FluidProperties”对话框,如图7-29所示,采用默认设置。

978-7-111-44902-7-Chapter07-131.jpg单击“OK”按钮会弹出“CFD Flow Properties”对话框,如图7-30所示,在“Density property type CONSTANT Constant value”输入框中输入rho,在“Viscosity property type CONSTANT Constant value”输入框中输入mu,其余选项采用默认设置,单击“OK”按钮关闭该对话框。

978-7-111-44902-7-Chapter07-132.jpg(www.xing528.com)

图7-27 “Advection Option”对话框

978-7-111-44902-7-Chapter07-133.jpg

图7-28 “DOF Relaxation”对话框

978-7-111-44902-7-Chapter07-134.jpg

图7-29 “Fluid Properties”对话框

978-7-111-44902-7-Chapter07-135.jpg

图7-30“CFD Flow Properties”对话框

978-7-111-44902-7-Chapter07-136.jpg依次选择Utility Menu→Select→Everything。

978-7-111-44902-7-Chapter07-137.jpg依次选择Main Menu→Solution→Run FLOTRAN,求解完成后会弹出提示对话框,单击“Close”按钮关闭。迭代曲线如图7-31所示。

978-7-111-44902-7-Chapter07-138.jpg

图7-31 迭代曲线

注意

有些多核处理器的计算机在计算时出现如图7-32所示的错误对话框,则需要将并行计算关闭,按图7-33所示在“Mechanical APDL Product Launcher”对话框中将处理器的数量设为1。

978-7-111-44902-7-Chapter07-139.jpg

图7-32 错误对话框

978-7-111-44902-7-Chapter07-140.jpg

图7-33 “Mechanical APDL Product Launcher”对话框

免责声明:以上内容源自网络,版权归原作者所有,如有侵犯您的原创版权请告知,我们将尽快删除相关内容。